Gulf Coast Conference 2026

Mixer Mill MM-4000

Image shows Mixer Mill MM-4000 by Verder Scientific on a white background.

Mixer Mill MM-4000

The most versatile all-rounder of ball mills

The Mixer Mill MM-4000 is a true multipurpose mill designed for dry, wet, and cryogenic grinding of small volumes up to 2 x 20 ml. It mixes and homogenizes powders and suspensions with a frequency of 30 Hz within seconds – unbeatably fast and easy to operate. The compact benchtop unit is suitable for classic homogenization processes, as well as for biological cell disruption for DNA/RNA and protein extraction. Long processing times up to 99 hours make the MM-4000 ideally suited for research applications, for example in mechanochemistry. With regard to performance and flexibility of this mill, there is no equivalent technology available in the market.

Performance & Design

  • Powerful size reduction and homogenization by impact and friction with up to 30 Hz
  • Equipped with 2 grinding stations for up to 20 samples per run
  • Memory for 12 Standard Operating Procedures (SOP) and 6 program cycles
  • Convenient touch display, significant noise reduction
PREMIER Lab Supply is an authorized distributor of Verder Scientific.
More Info Brochure
Image shows close up view of Mixer Mill 4000.

Recommended Jar Fillings

The jar size should be adapted to the sample volume to ensure optimum results. Ideally, the grinding balls are three (3) times the size of the largest sample piece. The numbers and sizes of balls provided in the table follow this rule of thumb.
Grinding Jar Nominal Volume Sample Amount Max. Feed Size Recommended Ball Charge (pieces)
Ø 5mm Ø 7mm Ø 10mm Ø 12mm Ø 15mm Ø 20mm Ø 25mm
1.5 mL 0.2 - 0.5 mL 1 mm 1 - 2 - - - - - -
5 mL 0.5 - 2 mL 2 mm - 1 - 2 - - - - -
10 mL 2 - 4 mL 4 mm - 5 - 7 1 - 2 1 - 2 - - -
25 mL 4 - 10 mL 6 mm - - 5 - 6 2 - 4 1 - 2 - -
35 mL 6 - 15 mL 6 mm - - 6 - 9 4 - 6 2 - 3 1 -
50 mL 8 - 20 mL 8 mm - - 12 - 14 6 - 8 3 - 4 1 1

Typical Sample Materials

The MM-4000 can homogenize alloys, animal feed, bones, ceramics, cereals, chemical products, coal, coke, drugs, electronic scrap, glass, grains, hair, minerals, oil seeds, ores, paper, plant materials, plastics, sewage sludge, soils, straw, tablets, textiles, tissue, tobacco, waste samples, wood, wool, etc.

Technical Specifications

Applications size reduction, mixing, homogenization, cell disruption, cryogenic grinding, mechanochemistry
Feed material hard, medium-hard, soft, brittle, elastic, fibrous
Size reduction principle impact, friction
Material feed size* / Final Fineness* <= 8 mm / ~ 5 μm
Batch size / feed quantity* max. 2 x 20 ml
Number of grinding stations 2
Vibrational frequency 3 - 30 Hz (180 - 1800 min-1)
Typical mean grinding time / Max. grinding time 30 s - 2 min / 99 hr
Dry, wet & cryogenic grinding √
Cell disruption with reaction vials √, up to 20 x 20 mL
Self-centering clamping device √
Type of grinding jars screw top design
Material of grinding tools hardened steel, stainless steel, tungsten carbide, agate, zirconium oxide, PTFE, PMMA
Grinding jar sizes 1.5 ml / 5 ml / 10 ml / 25 ml / 35 ml / 50ml
Setting of grinding time digital, 10 s - 8 h
Storable SOPs / Cycle Programs 12 SOPs / 6 Programs
Electrical supply data 100-240 V, 50/60 Hz
Power connection / Power Consumption 1-phase / 165W
Protection code IP 30
W x H x D closed 385 x 350 x 470 mm

Image shows Mixer Mill MM-4000 by Verder Scientific on a white background.

Mixer Mill MM-4000

The most versatile all-rounder of ball mills

The Mixer Mill MM-4000 is a true multipurpose mill designed for dry, wet, and cryogenic grinding of small volumes up to 2 x 20 ml. It mixes and homogenizes powders and suspensions with a frequency of 30 Hz within seconds – unbeatably fast and easy to operate.

Performance & Design

  • Powerful size reduction and homogenization by impact and friction with up to 30 Hz
  • Equipped with 2 grinding stations for up to 20 samples per run
  • Memory for 12 Standard Operating Procedures (SOP) and 6 program cycles
  • Convenient touch display, significant noise reduction
PREMIER Lab Supply is an authorized distributor of Verder Scientific.
brochure

Key features

Jar Fillings

Recommended Jar Fillings

The jar size should be adapted to the sample volume to ensure optimum results. Ideally, the grinding balls are three (3) times the size of the largest sample piece. The numbers and sizes of balls provided in the table follow this rule of thumb.
Grinding Jar Nominal Volume Sample Amount Max. Feed Size Recommended Ball Charge (pieces)
Ø 5mm Ø 7mm Ø 10mm Ø 12mm Ø 15mm Ø 20mm Ø 25mm
1.5 mL 0.2 - 0.5 mL 1 mm 1 - 2 - - - - - -
5 mL 0.5 - 2 mL 2 mm - 1 - 2 - - - - -
10 mL 2 - 4 mL 4 mm - 5 - 7 1 - 2 1 - 2 - - -
25 mL 4 - 10 mL 6 mm - - 5 - 6 2 - 4 1 - 2 - -
35 mL 6 - 15 mL 6 mm - - 6 - 9 4 - 6 2 - 3 1 -
50 mL 8 - 20 mL 8 mm - - 12 - 14 6 - 8 3 - 4 1 1

Sample Materials

Typical Sample Materials

The MM-4000 can homogenize alloys, animal feed, bones, ceramics, cereals, chemical products, coal, coke, drugs, electronic scrap, glass, grains, hair, minerals, oil seeds, ores, paper, plant materials, plastics, sewage sludge, soils, straw, tablets, textiles, tissue, tobacco, waste samples, wood, wool, etc.

specifications

Applications size reduction, mixing, homogenization, cell disruption, cryogenic grinding, mechanochemistry
Feed material hard, medium-hard, soft, brittle, elastic, fibrous
Size reduction principle impact, friction
Material feed size* / Final Fineness* <= 8 mm / ~ 5 μm
Batch size / feed quantity* max. 2 x 20 ml
Number of grinding stations 2
Vibrational frequency 3 - 30 Hz (180 - 1800 min-1)
Typical mean grinding time / Max. grinding time 30 s - 2 min / 99 hr
Dry, wet & cryogenic grinding √
Cell disruption with reaction vials √, up to 20 x 20 mL
Self-centering clamping device √
Type of grinding jars screw top design
Material of grinding tools hardened steel, stainless steel, tungsten carbide, agate, zirconium oxide, PTFE, PMMA
Grinding jar sizes 1.5 ml / 5 ml / 10 ml / 25 ml / 35 ml / 50ml
Setting of grinding time digital, 10 s - 8 h
Storable SOPs / Cycle Programs 12 SOPs / 6 Programs
Electrical supply data 100-240 V, 50/60 Hz
Power connection / Power Consumption 1-phase / 165W
Protection code IP 30
W x H x D closed 385 x 350 x 470 mm